Air conditioning equipment is a unit produced by integrating different devices into a unit in order to make the air supplied into the room suitable for the purpose of use.
Air conditioning equipment is comprised of a mixing coil which mixes the air re-circulated into the air with fresh outside air, a cooling coil which reduces moisture in the air during cooling, a heating coil which heats up the air during heating, an air filter which removes impurities such as dust mixed in the air, and a humidifier which sprays water or vapor for humidification during heating, and an eliminator is also installed in some cases for prevention of humidification water from being re-scattered when the wind speed is high.
The quality of the air conditioning equipment manufactured by C&G Technology Co., Ltd. is guaranteed as the components are manufactured in the factory under a plan by type and specification, and the site installation work is also efficiently conducted. Also, large products are designed to allow easy transportation, warehousing and site assembly as they are produced being divided into the blower part, coil part, and filter part.
A clean room means the space in which the concentration of air floating particles is controlled to be below the specified cleanliness level, the required cleanliness is also maintained for the materials, chemicals, and water supplied to the space, and the environmental conditions such as temperature, humidity, static electricity, indoor pressure, noise and vibration are also controlled and managed as necessary.
Besides, the shape and speed of the indoor air current, harmful gas and indoor illuminance are also required to be included in the items to be managed.
And, clean room is diversely applied not only in the semi-conductor industry but also to a wide range such as precision industry, medicine production, food manufacturing industry, optical machines, hospitals and laboratories.
A bio clean room means a clean room space in which living things and inorganic particles in the indoor air are controlled.
Item | Vertical Laminar Airflow Clean Room | Horizontal Laminar Airflow Clean Room | Turbulent Airflow Clean Room | Mixed Airflow Clean Room | Tunnel Clean Room |
---|---|---|---|---|---|
Vertical Laminar Airflow Clean Room | Horizontal Laminar Airflow Clean Room | Turbulent Airflow Clean Room | Mixed Airflow Clean Room | Tunnel Clean Room | |
Cleanliness | M1.5~3.5 (Class 1~100) |
M3.5 (Class 100) |
M4.5~6.5 (Class 1000~100000) |
M4.5~6.5 (Class 1000~100000) |
M1.5~3.5 (Class 1~100) |
Cleanliness during Operation | The effect of the workers is small. | Oscillation of the upper stream part has an effect on the lower stream part. | There is no effect of the workers. | There is a little effect of the workers depending on the layout. | The effect of the workers is the smallest. |
Operation cost | High | Medium | Low | Medium | Medium |
Layout change | Easy | Difficult | Easy | Easy | Difficult |
Manufacturing device repair | To be conducted from the inside of the room or return space | To be conducted from the inside of the room or return space | To be conducted from the inside of the room | To be conducted from the inside of the room or return space | To be conducted from the return space |
Extensibility | Difficult | Difficult | Somewhat difficult | Difficult | Every line is extensible. |
Precision control | Due to the control over the whole room, a little unbalance exists in the room | Heat generation at the upper stream part has an effect on the lower stream part. | Unbalance exists. | Unbalance exists | Each worker can be controlled with high precision. |
Type |